Mouse monoclonal antibody Anti-Human MYBL2
|


|
|
|
| The protein encoded by this gene, a member of the MYB family of transcription factor genes, is a nuclear protein involved in cell cycle progression. The encoded protein is phosphorylated by cyclin A/cyclin-dependent kinase 2 during the S-phase of the cell cycle and possesses both activator and repressor activities. It has been shown to activate the cell division cycle 2, cyclin D1, and insulin-like growth factor-binding protein 5 genes. Transcript variants may exist for this gene, but their full-length natures have not been determined. [NCBI Entrez Gene Summary] |

|
|
|
|
|
Detection of MYBL2 by Western blot.
Samples: Whole cell lysate from human HEK293 (H, 25 μg) , mouse NIH3T3 (M, 25 μg) and rat F2408 (R, 25 μg) cells. [Lot No. MYBAD10A-2]
Predicted molecular weight: 78 kDa |
| |
Western blot protocol
|
|
 |
|
|
Immunostaining analysis in HeLa cells. HeLa cells were fixed with 4% paraformaldehyde and permeabilized with 0.1% Triton X-100 in PBS. The cells were immunostained with anti-MYBL2 mAb. [Lot No. MYBAD10A-2] |
| |
Immunocytochemistry protocol
|
|
 |
|
|
|
|
|
Left : Western blot analysis of immunized recombinant protein, using anti-MYBL2 monoclonal antibody.
Right : CBB staining of immunized recombinant protein.
Arrow indicates the region of immunized recombinant protein carrying 50-200 amino acids. |
|
|
| Antibody Concentration |
100 μg/ml (1.0 ml) |
| Host Species |
Human |
| Preparation |
This antibody was purified using protein G column chromatography from culture supernatant of hybridoma cultured in a medium containing bovine IgG-depleted (approximately 95%) fetal bovine serum. |
| Sterility |
Filtered through a 0.22 μm membrane. |
| Alternate Names |
BMYB, MGC15600 |
| Accession No. |
NM_002466 |
| Purchase |
Ordering information
|
|
|
|
| Caution must be taken to avoid contact with skin or eyes. In such a case, rinse thoroughly at once with water. Do not ingest, inhale, or swallow. Seek medical attention immediately. Wear appropriate protective clothing such as laboratory overalls, safety glasses and gloves. It is strongly advised that this product should be handled by people who have been well trained in laboratory techniques and that it is handled with care pursuant to the principles of good laboratory practice. All chemicals are deemed potentially harmful. The vial is prone to fall over. Use caution, especially when the lid is off . |
|
|
FOR RESEARCH USE ONLY, NOT FOR USE IN DIAGNOSTIC PROCEDURES.
|
|
|
|