Mouse monoclonal antibody Anti-Human BAZ1B

Catalog No. BMR00275 ¡ÎBAZ1H4H9¡Ï Data Sheet  

¢£Background 
This gene encodes a member of the bromodomain protein family. The bromodomain is a structural motif characteristic of proteins involved in chromatin-dependent regulation of transcription. This gene is deleted in Williams-Beuren syndrome, a developmental disorder caused by deletion of multiple genes at 7q11.23. [NCBI Entrez Gene Summary]

¢£Application Data
Detection of human BAZ1B by Western blot. Samples: Whole cell lysate (25 μg) from HeLa cells. [Lot No. BAZ1H4H9-2]

Predicted molecular weight: 176 kDa
  Western blot protocol 
HeLa cells were fixed in 2% paraformaldehyde/PBS and then permeabilized in 90% methanol. Cells were stained with anti-BAZ1B mAb (shaded) or isotype control (unshaded) followed by Alexa Fluor(R) 488-conjugated goat anti-mouse IgG. [Lot No. BAZ1H4H9-2]
  Flow cytometry protocol 
Immunostaining analysis in HeLa cells. HeLa cells were fixed with 4% paraformaldehyde and permeabilized with 0.1% Triton X-100 in PBS. The cells were immunostained with anti-BAZ1B mAb. [Lot No. BAZ1H4H9-1]
  Immunocytochemistry protocol 

¢£Quality of Control
Western blot analysis of immunized recombinant protein, using anti-BAZ1B monoclonal antibody.


Arrow indicates the region of immunized recombinant protein carrying 50-200 amino acids.
Antibody Concentration 100 μg/ml (1.0 ml)
Host Species Human
Preparation This antibody was purified using protein G column chromatography from culture supernatant of hybridoma cultured in a medium containing bovine IgG-depleted (approximately 95%) fetal bovine serum.
Sterility Filtered through a 0.22 μm membrane.
Alternate Names
Accession No. AB032253
Purchase Ordering information
Caution must be taken to avoid contact with skin or eyes. In such a case, rinse thoroughly at once with water. Do not ingest, inhale, or swallow. Seek medical attention immediately. Wear appropriate protective clothing such as laboratory overalls, safety glasses and gloves. It is strongly advised that this product should be handled by people who have been well trained in laboratory techniques and that it is handled with care pursuant to the principles of good laboratory practice. All chemicals are deemed potentially harmful. The vial is prone to fall over. Use caution, especially when the lid is off .
FOR RESEARCH USE ONLY, NOT FOR USE IN DIAGNOSTIC PROCEDURES.