BIO MATRIX RESEARCH, INC   close
BIO MATRIX RESEARCH(TM)
Ordering information
Mouse monoclonal antibody Anti-Human BMS1L

Catalog No. BMR00377 ¡Î2081C1a¡Ï Data Sheet  

¢£Background 
May act as a molecular switch during maturation of the 40S ribosomal subunit in the nucleolus. [UniProtKB Function]

¢£Application Data
Detection of human BMS1L by Western blot. Samples: Whole cell lysate (25 μg) from HeLa cells. [Lot No. 2081C1a-1]

Predicted molecular weight: 145 kDa
  Western blot protocol 
Immunoprecipitation: RIPA lysate of HeLa cells was incubated with anti-BMS1L mAb. [Lot No. 2081C1a-1]

Predicted molecular weight: 145 kDa
  Immunoprecipitation protocol 
HeLa cells were fixed in 2% paraformaldehyde/PBS and then permeabilized in 90% methanol. Cells were stained with anti-BMS1L mAb (shaded) or isotype control (unshaded) followed by Alexa Fluor(R) 488-conjugated goat anti-mouse IgG. [Lot No. 2081C1a-1]
  Flow cytometry protocol 
Immunostaining analysis in HeLa cells. HeLa cells were fixed with 4% paraformaldehyde and permeabilized with 0.1% Triton X-100 in PBS. The cells were immunostained with anti-BMS1L mAb. Nuclear was stained with Hoechst (blue fluorescence). [Lot No. 2081C1a-1]
  Immunocytochemistry protocol 

¢£Quality of Control
Western blot analysis of immunized recombinant protein, using anti-BMS1L monoclonal antibody.


Arrow indicates the region of immunized recombinant protein carrying 50-200 amino acids.
Antibody Concentration 100 μg/ml (1.0 ml)
Host Species Human
Preparation This antibody was purified using protein G column chromatography from culture supernatant of hybridoma cultured in a medium containing bovine IgG-depleted (approximately 95%) fetal bovine serum.
Sterility Filtered through a 0.22 μm membrane.
Alternate Names KIAA0187
Accession No. NM_014753
Purchase Ordering information
Caution must be taken to avoid contact with skin or eyes. In such a case, rinse thoroughly at once with water. Do not ingest, inhale, or swallow. Seek medical attention immediately. Wear appropriate protective clothing such as laboratory overalls, safety glasses and gloves. It is strongly advised that this product should be handled by people who have been well trained in laboratory techniques and that it is handled with care pursuant to the principles of good laboratory practice. All chemicals are deemed potentially harmful. The vial is prone to fall over. Use caution, especially when the lid is off .
FOR RESEARCH USE ONLY, NOT FOR USE IN DIAGNOSTIC PROCEDURES.