BIO MATRIX RESEARCH, INC   close
BIO MATRIX RESEARCH(TM)
Ordering information
Mouse monoclonal antibody Anti-Human KPNA4

Catalog No. BMR00485 ¡Î2500D3a¡Ï Data Sheet  

¢£Background 
The nuclear import of karyophilic proteins is directed by short amino acid sequences termed nuclear localization signals (NLSs). Karyopherins, or importins, are cytoplasmic proteins that recognize NLSs and dock NLS-containing proteins to the nuclear pore complex. The protein encoded by this gene shares the sequence similarity with Xenopus importin-alpha and Saccharomyces cerevisiae Srp1. This protein is found to interact with the NLSs of DNA helicase Q1 and SV40 T antigen. [NCBI Entrez Gene Summary]

¢£Application Data
Detection of KPNA4 by Western blot. Samples: Whole cell lysate from human HT-1080 (H, 25 μg) , mouse NIH3T3 (M, 25 μg) and rat F2408 (R, 25 μg) cells. [Lot No. 2500D3a-1]

Predicted molecular weight: 57 kDa
  Western blot protocol 
Immunostaining analysis in HeLa cells. HeLa cells were fixed with 4% paraformaldehyde and permeabilized with 0.1% Triton X-100 in PBS. The cells were immunostained with anti-KPNA4 mAb. [Lot No. 2500D3a-1]
  Immunocytochemistry protocol 

¢£Quality of Control
Western blot analysis of immunized recombinant protein, using anti-KPNA4 monoclonal antibody.


Arrow indicates the region of immunized recombinant protein carrying 50-200 amino acids.
Antibody Concentration 100 μg/ml (1.0 ml)
Host Species Human
Preparation This antibody was purified using protein G column chromatography from culture supernatant of hybridoma cultured in a medium containing bovine IgG-depleted (approximately 95%) fetal bovine serum.
Sterility Filtered through a 0.22 μm membrane.
Alternate Names QIP1, SRP3, IPOA3, MGC12217, MGC26703
Accession No. NM_002268
Purchase Ordering information
Caution must be taken to avoid contact with skin or eyes. In such a case, rinse thoroughly at once with water. Do not ingest, inhale, or swallow. Seek medical attention immediately. Wear appropriate protective clothing such as laboratory overalls, safety glasses and gloves. It is strongly advised that this product should be handled by people who have been well trained in laboratory techniques and that it is handled with care pursuant to the principles of good laboratory practice. All chemicals are deemed potentially harmful. The vial is prone to fall over. Use caution, especially when the lid is off .
FOR RESEARCH USE ONLY, NOT FOR USE IN DIAGNOSTIC PROCEDURES.
PAGE TOPۯ

BIO MATRIX RESEARCH(TM)

Copyright©2006 BIO MATRIX RESEARCH, INC. All Rights Reserved.